The World's Largest Independent Manufacturer of UL LISTED Power Distribution Cable Assemblies.

Our Mission

The Power Cabling Corporation is the world's leading independent manufacturer of UL listed power distribution cable assemblies.  We are dedicated to our customers and to our employees, realizing that you truly do "reap what you sow".  We also stand behind our products with the industry's most comprehensive guarantee.  PCC warrants it's manufactured products and assemblies to be free from defects in material and workmanship under normal use for life.  No other manufacturer offers this blanket guarantee because no other manufacturer takes the pride and makes the effort to insure that their customers get the very best that they can give.  We do.  The first time, every time.

Every cable manufactured by the Power Cabling Corporation meets the high standards of quality established by Underwriters Laboratories.  We not only make custom power cable assemblies to your individual specifications, but we stock the most common configurations in various lengths, ready to ship the same day ordered.  We make power cables.  That's all we do.  Simply put, we will do whatever it takes to keep our customers satisfied.

 

Liquid Tight Power Distribution Cable Specification

Established for Underwriters Laboratories®

 

General

All cables manufactured by the Power Cabling Corporation consist of flexible metal conduit containing the required insulated power, neutral and ground conductors as established by the National Electric Code. The power cable shall include an insulated, liquid tight, flexible and interlocking wound steel armored outer shield, which surrounds all of the conductors to minimize electrical and or mechanical disturbances to the conductors. The flexible conduit shall contain a continuous copper ground conductor built into the core. The flexible conduit shall be blue in color throughout its length to provide positive identification of data processing power cabling. Material used for the outer shield shall conform to and be listed to UL Standard for Safety No. 360 (Conduit, Electrical, Liquid-Tight Flexible Steel). The "load" end of the output distribution cable shall be terminated in one of the following three ways as specified by the purchaser on a schedule provided separately from this specification.

 

1). A field-wired termination shall consist only of the specified length of Listed liquid tight conduit, 2 - Listed, insulated, straight liquid tight connectors, and the specified number of Listed conductors including a minimum of 18" of free conductors exiting the power cable at the "load" end.

2). A box-mounted receptacle termination shall consist of a Listed cast metal outlet box of water resistant design with threaded internal hubs, equipped with a Listed metal cover plate secured with screws to the outlet box and the appropriate Listed receptacle, 2 - Listed, insulated straight liquid tight connectors and the specified number of Listed conductors in the specified length of Listed liquid tight conduit.

3). An in-line or pin and sleeve termination shall consist of a circular in-line Listed connector-body in a water resistant housing, 2 - Listed, insulated straight liquid tight connectors and the specified number of Listed conductors in the specified length of Listed liquid tight conduit.

 

All cables shall contain a minimum of 60 inches (5 feet) of free conductors for attachment to power source.

 

Standards

The output conductors, liquid tight flexible metal conduit and fittings shall be sized in accordance with the National Electric Code and are Listed by Underwriters Laboratories and bear the appropriate UL mark. Each output cable shall be individually listed under UL Standard for Safety No. 478 as an NEC type "DP" (Data Processing) cable assembly.

 

Markings

Each output distribution cable shall be permanently labeled at each end of the cable with the UL mark, registration number, length and individual identification numbers.

 

Testing

All cables shall be thoroughly inspected at the factory for any defects in workmanship. All cables shall be tested for ground integrity, insulation leaks and proper phase rotation. All conductors shall be "Hi-Pot" tested at twice rated circuit voltage plus 1000 volts and pass the "Production Line Dielectric Withstand Test" using Biddle Model 212359 test equipment.

Power Cabling Corporation 312 East Main Street Westfield, PA 16950